MATERIAL SAFETY DATA SHEET
09. Physical and chemical properties
Physical state: Pastelike
Colour: Green-Blue
Odour: Characteristic
10 % pH-value: n.av.
Boiling point/boiling range (°C): n.av.
Drop point (°C): >260
Autoflammability: n.c.
Minimum limit of explosion: n.a.
Maximum limit of explosion: n.a.
Vapour pressure: n.c.
Density (g/ml): ~ 0,90
Water solubility: Insoluble
Viscosity: n.a.
10. Stability and reactivity
11. Toxicological information
Conditions to avoid:
See point 7. Stable when handled and stored correctly. Protect from humidity.
Materials to avoid:
See point 7. Avoid contact with strong oxidizing agents. Avoid contact with other chemicals.
Hazardous decomposition products:
See point 5.3
Ingestion, LD50 rat oral (mg/kg): n.av.
Inhalation, LC50 rat inhal.(mg/l/4h): n.av.
Skin contact, LD50 rat dermal (mg/kg): n.av.
Eye contact: n.av.
Sensitization: n.c.
Carcinogenicity: n.c.
Mutagenicity: n.c.
Reproductive toxicity: n.c.
Narcosis: n.c.
Exposure controls
Ensure good ventilation. This can be achieved by local suction or general air extraction.
If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn.
Applies only if maximum permissible exposure values are listed here.
General hygiene measures for the handling of chemicals are applicable.
Wash hands before breaks and at end of work.
Keep away from food, drink and animal feedingstuffs.
Respiratory protection: Normally not necessary. If OES or MEL is exceeded. Filter A - P2 (EN 141)
Hand protection: Recommended. Protective nitrile gloves (EN 374)
Eye protection: If applicable. Tight fitting protective goggles with side protection (EN 166).
Skin protection: Protective working garments (e.g. safety shoes EN 344, long-sleeved protective working garments).
Additional information on hand protection - No tests have been performed.
Selection made for preparations according to the best available knowledge and information on the ingredients.
Selection of materials derived from glove manufacturer's indications.
Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account.
Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from
manufacturer to manufacturer.
In the case of preparations the resistance of glove materials cannot be calculated in advance so it has to be tested before use.
The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.
Acute toxicity and immediate effects
Delayed and chronic effects
09.
10.
11.
Page 3/5
Printing Date 01.03.2010
Reviewed on 01.03.2010
Vue de la page 2